MILL YARD / CHANGE ORDER 02. Relocate the sole inter-storey stair out of the old stair room and turn its entire upper-floor enclosure into a daylighted study. Provide an actual, coordinated intervention in the surveyed two-storey building. Read the attached raster (both plans, section datums and facade survey). Coordinates and all numeric answers are decimal FEET. North is up, x east, y south. Submit only one JSON object per the schema below.

1. Use one labeled six-foot-wide retrofit bay. The straight flight rises north from the lower common hall to the upper common hall. The lower level landing must extend south from the low flight end and touch the lower hall, while the upper landing extends north from the high flight end and touches the upper hall. Landings may project into the halls, but leave at least 3 ft of the original hall depth clear. Keep both landings and flight inside the selected bay's lateral limits. Each landing has the exact flight width and a depth of 3..5 ft. Flight lies wholly between the two hall faces; flight clear width 3.5..4.5 ft.

2. Riser between 0.50 and 0.625 ft inclusive, tread 0.85..1.0 ft inclusive. N uniform risers span both floor datums. Flight run = (N−1) × tread; low and high ends match the interior edges of their landings. The new rectangular slab opening must start at the high flight end, clear each side of the flight by 0.25..0.5 ft, and end within the flight before the low end. Retain every surveyed beam and locked room. Do not overlap their area with the new void. The upper landing must also keep clear of the locked rooms. The part of the flight beneath retained slab and the part beneath ANY beam each require 6.75 ft vertical clearance. For this survey exercise use our continuous nosing pitch envelope z = upper floor level − (y−highY)×rise/tread for highY <= y <= lowY. Check the highest envelope point under each obstruction, including the edge of the cutout and the north face of each beam. Beam and cutout edges may touch.

3. Close the entire old opening on its surveyed perimeter and keep the entire enclosed former stair room as the new study. Upper hall connects directly through a 3..4 ft door cut into the allowed north-wall break. Leave both locked-room footprints unchanged in survey order [archive,plant]. Provide one study window entirely inside one allowable east-wall pocket. Sill 2..7 ft, head below or at surveyed limit, head greater than sill (relative to the upper floor). Daylight glazing = window plan length × clear height; provide at least 10% of measured study area. Enforce the privacy sill where the window overlaps the neighbor exposure.

4. Transfer the geometry to the section, elevation and schedule. Section uses an independent copy of the cut limits. Elevation y coordinates run along the east wall; z values in elevation are ABSOLUTE. Report actual clear glazed area and stair run. Coordinates accurate to 0.01 ft; rounded products within 0.03 ft (0.10 sq ft for area) are accepted. Each separately measured review condition earns one point.

Schema (replace every placeholder): {"lower":{"bay":"A or B or C","flight":[west,highY,east,lowY],"landing":[west,north,east,south]},"upper":{"landing":[west,north,east,south],"opening":[west,north,east,south],"infill":[west,north,east,south],"study":[west,north,east,south],"locks":[[west,north,east,south],[west,north,east,south]],"door":[x1,y1,x2,y2],"window":[x1,y1,x2,y2]},"section":{"floors":[lowZ,highZ],"slabSoffit":z,"beamSoffit":z,"cut":[northY,southY],"risers":N,"rise":r,"tread":t},"elevation":{"glass":[northY,southY,sillZ,headZ]},"schedule":{"stairRun":length,"glassArea":area}}